Roof Ceiling Fire Rated Assemblies
Have a question about assemblies.
Roof ceiling fire rated assemblies. Floor ceiling. If you are unfamiliar with ul fire resistance ratings begin with a review of meeting code requirements pg. Concrete with cellular steel 3 hr. The fire resistance rating of a wood frame assembly is equal to the sum of the time assigned to the membrane on the fire exposed side the time assigned to the framing members and the time assigned for additional contribution by other protective measures such as insulation.
As applied to elements of buildings the fire resistance rating classifies the ability of an assembly to confine and isolate fire within a zone comprised of fire resistance rated walls ceiling and floor assemblies. Roof floor ceiling time assembly ff file no. Only fire guard products can be used in fire rated assemblies and are idenfified with the fire guard icon. As explained there these ratings are applied to certain types of roof ceiling and floor ceiling construction assemblies which are tested and assigned hourly ratings mandated by building codes or other building safety requirements.
These assemblies need to meet fire and smoke safety and environmental sustainability requirements. Meet astm e1264 class a rating. 276 fire rated ceiling assemblies suspension ceiling designs floor ceiling designs a003 3 hr. 3 4 fr 83 12 x 12 z runners fluorescent type none 2 1 2 concrete.
Helpful documents and resources for usg s roof assemblies can be found on this page. The reduction can also apply when code allows for a corridor wall to be a 30 minute assembly. Benefits of fire guard ceilings and grid. 2 x 8 16 o c span 12 live load 40 lbs w 3 4 t g plywood ceiling 1 2 non rated gwb.
2 x 10 16 o c span 12 14 live load 40lbs w 3 4 wood sheathing ceiling 3 8 gwb. 12 x 24 2 x 4 8 w10 x 25 beam floor units and beam support 3 hr. Urb concealed grid system and tile. Refer to our roof ceiling assembly documents which includes ul fire rated roof assemblies for easy guidance through the assembly of a roof or ceiling on your next project.
The ratings relate to fire tests designed to determine how quickly fire can raise the temperature to unacceptable levels. Fire safety caution passing a fire test in a controlled laboratory setting and or certifying or labeling a product as having a one hour two hour or any other fire resistance or protection rating and therefore as acceptable for use in certain fire rated assemblies systems does not mean that either a particular assembly system. Fire guard ceilings and grid systems are designed to provide enhanced resistance against structural failure.