Roof Setbacks Solar
The intention of the setbacks is to provide firefighters with access to the peak of the roof in order to provide positive ventilation in the event of a house fire.
Roof setbacks solar. This could due to a jurisdictional requirement a fire code requirement or a company design guideline. City of las vegas henderson north las vegas or clark county etc fire setbacks are distances that solar panels must not be placed within mostly near ridgelines or peaks valleys on the roof or other obstacles like skylights and chimneys to allow firefighters to safely walk on the roof when responding to building fire. But they are required in california. These requirements don t exist everywhere so check with your local authorities.
The exact size of the fire setback depends on the size of the building but for an average sized home each roof section that has solar panels requires two clear 36 inch wide pathways running along the edge of the roof. Any roof with pitch equal or less than 2 in 12 9 46 degrees doesn t require any setbacks pathways. According to cal fire s solar photovoltaic installation guidelines below are illustrations of currently enforced fire setbacks pathways for residential solar system installations. Posted october 18 2018.
Setbacks for solar pv systems are required by the ibc international building code and adopted by some state and local permitting authorities. Fire setbacks next lesson. You can easily define roof setbacks by clicking on settings in the top right hand corner of your site model. The international fire code 605 11 3 2 4 that states panels modules installed shall be located no higher than 3 ft below the ridge to allow for fire department ventilation operations significantly decreases the attractiveness of residential solar pv because it applies to both sides of a peaked roof.
This is a requirement imposed by the 2018 international fire code section 1204 and adopted by the authority having jurisdiction ahj i e. Home courses designing pitched roof solar arrays preliminary layout site surveying. For homes with sprinkler systems if the system takes up less than 2 3 of the plan view total roof area the setback for ridge ventilation is also relaxed to 18 inches.